Signal Data

From SICDB Doc
Revision as of 16:35, 18 September 2022 by Salkin (talk | contribs)
Jump to navigation Jump to search

Data Description

Various types of signal data has been included in the SICDb dataset. Signal data is saved in data_float_h table, value reference is found in d_references.

Important note: Data stored in data_float_h is aggregated hourly data.

Predefined Fields (RooDataServer)

Generic Signal
Name Description Comment Type
SignalCountHours Amount of hours where selected signal data is available O D
SignalAvg Average signal value of selected signal O D
SignalMin Minimum hourly average signal value of selected signal O D
SignalMax Maximum hourly average signal value of selected signal O D
SignalHoursUnderX Amount of hours, where the average signal value is under X O D
SignalHoursOverX Amount of hours, where the average signal value is >= X O D
SignalHoursBetweenXY Amount of hours, where the average signal value is >=Min and <Max O D
SignalStd Standard deviation of average hourly values of selected signal O D


Raw Fields

Caption text
Name Description Comment
CaseID Case identifier
DataID Reference stored in d_references DataID=ReferenceGlobalID
Offset Time in seconds after admission
Val Value
cnt Amount of values aggregated
rawdata List of 60 floats containing raw data Due to excessive storage needs minute values have been aggregated.

Aggregation Description

Most signal data is averaged. The field data_float_h.cnt describes the amount of values aggregated. It is to be expected that the first signal values have less than 60 data points, as it is quite unlikely (1:60) that signal starts on minute 0.

Raw values are saved in field data_float_h.rawdata, being a list of bytes. (IEEE 754 Single(4 bytes), LittleEndian)

Metavision does, in database, not differentiate between qualitative (i.e. blood pressure) and quantitative (i.e. drainage volume) data, this was done programatically saving the sum instead of average.

Known Limitations

0 Values

All values were aggregated to hourly average values. As in many cases Metavision saves 0 values during signal loss times instead of NULL aggregating these would significantly influence statistics. Think about a patient with constant MAP of 60 is disconnected for 15min, aggregating would result in a average MAP of 45. For this reason 0 values were set to NULL and ignored. This behaviour is expected to represent in nearly all cases the most likely value.

In very special cases, like cardioplegia, where 0 would be a correct pulse rate, expect values to be missing. Contact developer in case you need this data.